Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160

1
MOQ
Negotiated
Price
Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160
Features Gallery Product Description Request A Quote
Features
Specifications
Stage: X-Y Double Layer Compound Mechanical Stage
Magnification: 500X
Microscope Monitor: Color LCD Monitor 10 Inch(4:3)
Brightness Of The Light Source: ≥ 600cd/m2
Output: DC12V,2A
Mechanical Stage: X-Y Double Layer Compound Mechanical Stage
Focusing Mechanism: Coaxial Coarse And Fine Adjustment
Built-in Camera: 80 000 Pixels
High Light:

capillary microscope

,

nail microscope

Basic Infomation
Place of Origin: China (Mainland)
Brand Name: SSCH( Suyzeko)
Certification: CE
Model Number: GY-160
Payment & Shipping Terms
Packaging Details: carton box packing
Delivery Time: 5-7 days after receiving payment
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 3000pcs per month
Product Description

Professional Portable Biological Microcirculation Microscope Capillary Microscope Digital

 

Blood microcirculation:

1. Model GY-160(10inch color LCD)
2. For health care&beautiful industry
3 Independent research and development ability
4. nailfold microcirculation microscope is a noninvasive health diagnostic device

 

What's micro circulation ?

Microcirculation is the circulation of the blood in the smallest blood vessels,present in the vasculature embedded within organ tissues. This contrasts with macrocirculation, which is the circulation of blood to and from the organs. Microcirculation is composed of terminalarterioles, capillaries capillaries and venules which drain capillary blood. The vessels on the arterial side of the microcirculation are called the arterioles, which are well innervated, are surrounded by smooth musclecells, and are 10-100 µm in diameter.
Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors, microcirculation appears white tiny blood clots, which with the blood flow in the body.
Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.

 

Microcirculation is usually very smooth, but by high blood lipids, blood viscosity, erythrocyte aggregation, affect cardiovascular disease and other factors,microcirculation appears white tiny blood clots, which with the blood flow in the body.
Once the blood vessels become thin, distorted and clog the blood vessels (especially the elderly), there will be a corresponding disease, ranging from dizziness, insomnia, dizziness, numb lips, palpitation, chest tightness. If there is a large area of the brain or heart blockage will cause
hemiplegia, language barriers, myocardial infarction. Therefore, early detection of thrombosis should check the microcirculation by actively antithrombotic thrombolysis, and clear the microcirculation, preventive measures.
Currently, the primary means of discovery is microcirculation microcirculation microscopic examination instrument, and general such as CT, MRI, X-ray, B-and so can not be found, so the clinical microcirculation earlier than macroscopic examination has found early diagnosis role.
Meanwhile, health groups and immunocompromised people are mainly in the microcirculation, lack of microvascular perfusion, vascular blurred, slow blood flow. By detecting the microcirculation can also quickly find the body in which the current situation in a timely manner as soon as possible be microcirculation, increase resistance and immunity, improve the sub-health conditions.
The Nailfold Capillaroscopy Microcirculation Microscope is an advance medical photoelectric apparatus,equipped with built in special LED light source,used mainly in observation on human nail fold capillary microcirculation or term as video Nailfold capillaroscopy,Such as capillary blood flow, abnormal microcirculation of the vascular structure, cell adhesion, through its powerful 380X(or 240X)optical magnification. Undistorted, real time dynamic video streaming via Sony CCD imaging device onto the LCD monitor screen.
Simply insert the finger to the holder below the optical lens apparatus, fine-tune to fix the focal length and uncover the desired images within seconds.Blood capilliary microcirculation microscope is a non-invasive diagnostic tools, which is gaining large credit among physicians of different specialities in for study of skin blood capilliary network.
 

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside .

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on .

 

Technical parameters:

 

Microscope Magnification ≥500 times
Built-in camera pixels 380000 pixels
Light source LED
Brightness of the light source ≥ 600cd/m2
Stage X-Y double layer compound mechanical stage
nailfold microcirculation microscope monitor colar LCD monitor 10inch(4:3)
Input&Output AC input 100~240V 50/60Hz DC output DC12V,2A
Microscope Package Aluminum box( Size 34*29*20cm)

 

Features:

1. in 5 seconds can be observed in the microvascular circulation, simple operation and fast;
2. the microscopic image is stable, clear, do not shake;
3. 500 times the microcirculation of a dedicated high-resolution lens of the microscope;
4. handheld ultra-light design, so that the observation of more mobility;
5. with micro-focus wheel, free to adjust the focus length, the use of more convenience
6. lens built-in LED cold light source, accurate projection illumination on an object;
7. using non-invasive way, to observe the microcirculation of human body in time;
8. observing the microcirculation for any part of human body.

 

Application:

1. nail wall distal microcirculation observation
2. cutaneous distal microcirculation observation
3. tongue microcirculation observation
4. the auricle distal microcirculation observation
5. lips microcirculation observation
6. the other parts of the microcirculation observed
7. sweat glands observed
8. hair follicles observed
9. bamboo charcoal commodity microcirculation efficiency testing
10.far- infrared commodity microcirculation efficiency testing
11. the germanium titanium micro-circulation of goods performance detection
12.ore commodity micro-cycle efficiency detection.

 

Distributed pattern for finger nail fold blood capillary

 

The observation for nail fold micro circulation is mainly from three aspects ,including the shape, the fluid state and the blood vessel ansa perimeter.

Normal state: Nail fold blood capillary arrangement neat, distribution even, the blood vessel ansa is clearly discernible.

Abnormal state: Arrangement disorder, blood vessel ansa fuzzy, is possible to because of the oxygen deficit, the blood stream to be impeded, the Asian health and so on causes.

 

Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160 0

 

Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160 1

 

Shape of blood vessel ansa :

(1) Normal shape likes the hair clip , exceptionally for overlapping and abnormal, the overlapping proportion number should not surpass 30%, the abnormal should not surpass 10%.

(2) abnormal blood vessel:

Explained: 1st, the blood vessel of heart and brain disease, the diabetes, the desmosis and so on, with contract whole body disease or the partial fungus infection and flesh wound and other organization disease is easy to appear the blood vessel to be abnormal

2nd, when arteriosclerosis, diabetes with serious abnormal , and the proportion excessive highly.

3rd, collagen disease, Reynold sickness, neurosis, the variation of blood vessel increases.

 

Blood vessel ansa’s periphery

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside.

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on.

 

Testing conditions:

1) Check the room temperature and humidity. Room temperature and humidity

should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%

2) the patient generally take seats, keep the height of the hand the same with heart

3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light

transmission, and reduce skin scattering)

4) Testing generally be in the morning or afternoon, and review should at the same time every day.

5) the patient should

a. Avoiding intense activity or manual labor within one hour before testing

b. Take a rest about 15-30 minutes before testing

c. Can not take any drug which will affect the cardiovascular vessels before testing

d. Does not smoke , wash hands or eat within an hour before testing

e. Pay attention to the influence of the Female menstrual

 

Professional Biological Capillary Microscope Digital DC12V 2A Output GY-160 2
 

Packaging & Shipping

  1. 1 pc/box. Deliver from Shenzhen, Guangdong.

  2. FedEx/DHL/UPS/TNT for samples, Door-to-Door;

  3. By Air or by Sea for batch goods, for FCL; Airport/ Port receiving;

  4. Customers specifying freight forwarders or negotiable shipping methods!

  5. Delivery Time: 2-5 days for samples; 5-7 days for bulk order.
    Normal packed by carton box, can be customized according to order quantity.

 

Service and Warranty
 
A. Warranty period
Our warranty includes the maintenance of material and manufacturing technology malfunctions within Thirteen months from the date you buy our machine.
 
B. Restriction
If the machine is not dated, we will be unable to provide you the service. We will not bear any responsibility if any damage caused by the followings: Damage caused by fire, earthquake, riots, or any force majeure.Incidental damage such as interruption of business and loss of business benefit including loss caused by using the machine, costs raised by any other machines’ replacement, installation and service, or claims of your customers.
 
C. Shipping problem
If you find there is something wrong while opening the packing, please contact shipping company at first time, both of us must discuss with relative shipping company to solve the problem. At the same time, we’ll do relative help for you.
 
Send your Inquiry Details in the Below, Click "Send" Now!
 
OEM Service Offered, Design Service Offered, Buyer Label Offered.

Recommended Products
Get in touch with us
Tel : +86-13631598551
Fax : 86-755-29500529
Characters Remaining(20/3000)