Specifications
Stage: X-Y Double Layer Compound Mechanical Stage
Magnification: 500X
Warranty: One Year
Built-in Camera Pixels: 380000 Pixels
Input&Output: AC Input 100~240V 50/60Hz DC Output DC12V,2A
Microscope Monitor: Color LCD Monitor 10 Inch(4:3)
Light Source: LED
Brightness Of The Light Source: ≥ 600cd/m2
High Light:

capillary microscope

,

nail microscope

Basic Infomation
Place of Origin: China (Mainland)
Brand Name: SSCH( Suyzeko)
Certification: CE
Model Number: GY-160
Payment & Shipping Terms
Packaging Details: carton box packing
Delivery Time: 5-7 days after receiving payment
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 3000pcs per month
Product Description

Portable 10 Inch LED Display Nailfold Capillaroscope/ Microcirculation Test Machine with CE
 

Blood microcirculation:

1. Model GY-160(10inch color LCD)
2. For health care&beautiful industry
3 Independent research and development ability
4. nailfold microcirculation microscope is a noninvasive health diagnostic device

 

What's micro circulation ?

The micro circulation is one of life basic characteristics, and is that the organism unceasingly carries on the matter, the energy and information transmission with the environment. The unicellular organism directly carries on transmission through the cell membrane, the extremity animal is carries on the transmission through the organization gap in blood lymph, but because of evolving to the mammal stage (for example human being), only has the lung ,the stomach and intestines separately carry on material, the energy, the information transmission through the trachea and the esophagus with the external environment, other organized the organ’s position, the function, the metabolism already to finalize, constitutes the organization and the cell of the organ, cannot be direct with the external environment communication, only through tissue fluid, the blood, and the lymph carry on material, the energy, the information transmission.
The micro circulation is by blood, the lymph and tissue fluid flowing which directly participates in the organization, the cell matter, the energy, the information transmission . May directly observe the blood flows in the thin artery, the blood capillary, and the thin vein through the micro circulation microscope , but if it does not do the special handling is that cannot see clearly the lymph and tissue fluid mobile, therefore, on clinical usually thought the micro circulation refers to the blood micro circulation in the blood capillary .
Directly the blood, the lymph, tissue fluid flowing which participating in the matter, the information, the energy transmission of organization, and the cell , is called the micro circulation 

 

Micro circulation characteristic

1. The micro circulation compares with the general circulation , has following five remarkable characteristics:

the micro circulation not only is the most end part of the circulatory system in the attribute , also the important part of the internal organs

Blood capillary, lymph capillarles all is the most end part of the circulatory system , belongs to the circulatory system. The many internal organs’ parenchima,and the organization all with the thin artery, the blood capillary, the thin vein as well as lymph capillarles organically unifies in together, forms the micrangium as the important support spatial structure, therefore they also are the important part of the internal organs .

 

2. The micro circulation both have the general character vessel in the shape, and has the internal organs’character.

Micrangium,and lymph capillarles assume the cavity tubular in the shape, is advantageous for the blood, lymph flowing. But the shape and the structure of micrangium all respectively have the characteristic in various internal organs, like intestinal villi, pulmonary alveolus, liver, marrow micrangium’s arrangement, shape and structure all quite same not less than. Even identical internal organs different from spot, like lymph node, internal organs ,its corpusculum medulla spot ‘s micrangium’s shape with each characteristic.

 

3. The micro circulation not only is the circuit of circulation in the function , also is the material interchange place. micrangium is the circulation circuit, the whole body’s circulation blood, besides partially flows after the artery,  the vein short-circuits, nearly completely flows after micrangium, pours into the organization, the cell. Tissue fluid- 6 - of exists to the organization, the cell gap of, flows between the blood micrangium, the cell, lymph capillarles , the lymph capillarle is one of the cell, organization's important output channels.Therefore the micro circulation is the place ,which the cell, the organization and the blood, the lymph carry on the material interchange 

 

 

4. Circulation is adjusted both by the whole body nerve, body fluid , and by mainly the partial adjustment

 

5. The micro circulation also has the common nature of the blood vessel, lymphatic vessel, metabolism the and so on organization gap , also displays its some characteristics of parenchyma metabolism in internal organs.

 

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside .

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on .

 

Technical parameters:

 

Microscope Magnification ≥500 times
Built-in camera pixels 380000 pixels
Light source LED
Brightness of the light source ≥ 600cd/m2
Stage X-Y double layer compound mechanical stage
nailfold microcirculation microscope monitor colar LCD monitor 10inch(4:3)
Input&Output AC input 100~240V 50/60Hz DC output DC12V,2A
Microscope Package Aluminum box( Size 34*29*20cm)

 

Features:

1. in 5 seconds can be observed in the microvascular circulation, simple operation and fast;
2. the microscopic image is stable, clear, do not shake;
3. 500 times the microcirculation of a dedicated high-resolution lens of the microscope;
4. handheld ultra-light design, so that the observation of more mobility;
5. with micro-focus wheel, free to adjust the focus length, the use of more convenience
6. lens built-in LED cold light source, accurate projection illumination on an object;
7. using non-invasive way, to observe the microcirculation of human body in time;
8. observing the microcirculation for any part of human body.

 

Application:

1. nail wall distal microcirculation observation
2. cutaneous distal microcirculation observation
3. tongue microcirculation observation
4. the auricle distal microcirculation observation
5. lips microcirculation observation
6. the other parts of the microcirculation observed
7. sweat glands observed
8. hair follicles observed
9. bamboo charcoal commodity microcirculation efficiency testing
10.far- infrared commodity microcirculation efficiency testing
11. the germanium titanium micro-circulation of goods performance detection
12.ore commodity micro-cycle efficiency detection.

 

Distributed pattern for finger nail fold blood capillary

 

The observation for nail fold micro circulation is mainly from three aspects ,including the shape, the fluid state and the blood vessel ansa perimeter.

Normal state: Nail fold blood capillary arrangement neat, distribution even, the blood vessel ansa is clearly discernible.

Abnormal state: Arrangement disorder, blood vessel ansa fuzzy, is possible to because of the oxygen deficit, the blood stream to be impeded, the Asian health and so on causes.

Portable 10 Inch LED Display Nail Fold Capillaroscopy Microcirculation Test Machine 0

Shape of blood vessel ansa :

(1) Normal shape likes the hair clip , exceptionally for overlapping and abnormal, the overlapping proportion number should not surpass 30%, the abnormal should not surpass 10%.

(2) abnormal blood vessel:

Explained: 1st, the blood vessel of heart and brain disease, the diabetes, the desmosis and so on, with contract whole body disease or the partial fungus infection and flesh wound and other organization disease is easy to appear the blood vessel to be abnormal

2nd, when arteriosclerosis, diabetes with serious abnormal , and the proportion excessive highly.

3rd, collagen disease, Reynold sickness, neurosis, the variation of blood vessel increases.

 

Blood vessel ansa’s periphery

After has carried on the shape and the fluid state observation, but also should carry on the observation to the periphery condition:

1. Seeps out: refers to, in the blood vessel, appears the phenomenon for the blood plasma ingredient excessively permeability blood pipe wall and the accumulation in blood capillary’s periphery , is one of common micro circulation changes. Characteristic: The blood vessel ansa periphery gap expands, and bright; The blood vessel ansa’s image is fuzzy, the length reduces.

2. Hemorrhage: phenomenon for the red blood cell leaves to the blood vessel outside.

Should distinguish the hemorrhage which the flesh wound or other non- pathogenesis factor creates, if the leakage hemorrhage, the main reason is blood capillary wall damage, causes the permeability hyperfunction and the blood flow changes and so on.

 

Testing conditions:

1) Check the room temperature and humidity. Room temperature and humidity

should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%

2) the patient generally take seats, keep the height of the hand the same with heart

3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light

transmission, and reduce skin scattering)

4)Testing generally be in the morning or afternoon, and review should at the same time every day.

5) the patient should

a.Avoiding intense activity or manual labor within one hour before testing

b. Take a rest about 15-30 minutes before testing

c.Can not take any drug which will affect the cardiovascular vessels before testing

d. Does not smoke , wash hands or eat within an hour before testing

e.Pay attention to the influence of the Female menstrual

 

 

Portable 10 Inch LED Display Nail Fold Capillaroscopy Microcirculation Test Machine 1

Portable 10 Inch LED Display Nail Fold Capillaroscopy Microcirculation Test Machine 2
 

Packaging & Shipping

  1. 1 pc/box. Deliver from Shenzhen, Guangdong.

  2. FedEx/DHL/UPS/TNT for samples, Door-to-Door;

  3. By Air or by Sea for batch goods, for FCL; Airport/ Port receiving;

  4. Customers specifying freight forwarders or negotiable shipping methods!

  5. Delivery Time: 2-5 days for samples; 5-7 days for bulk order.
    Normal packed by carton box, can be customized according to order quantity.

 

Service and Warranty
 
A. Warranty period
Our warranty includes the maintenance of material and manufacturing technology malfunctions within Thirteen months from the date you buy our machine.
 
B. Restriction
If the machine is not dated, we will be unable to provide you the service. We will not bear any responsibility if any damage caused by the followings: Damage caused by fire, earthquake, riots, or any force majeure.Incidental damage such as interruption of business and loss of business benefit including loss caused by using the machine, costs raised by any other machines’ replacement, installation and service, or claims of your customers.
 
C. Shipping problem
If you find there is something wrong while opening the packing, please contact shipping company at first time, both of us must discuss with relative shipping company to solve the problem. At the same time, we’ll do relative help for you.
 
Send your Inquiry Details in the Below, Click "Send" Now!
 
OEM Service Offered, Design Service Offered, Buyer Label Offered.

Recommended Products
Get in touch with us
Fax : 86-755-29500529
Characters Remaining(20/3000)