CE Approved And OEM Microcirculation Microscope with High definition Video Screen
Description
The microcirculation microscope is widely used in the field of hospitals, school laboratories, clinics, etc., as the best auxiliary testing equipment. And it is also used in health food industry, as a communication platform for product promotion when, making money equipment, beauty industry.
For it is non-invasive, only to observe the end of the finger armor section, you can do the blood microcirculation review. You can observe microcirculation pipe loop patterns, the number of pipe loop, blood flow, bleeding, etc., help determine the sub-health status and blood stasis and brain / cardiovascular related diseases.
Quick Detail
1.CE certificate
2.it is colorized ,image is much more clear
3.Color Microcirculation Microscope with coaxially conjugated hand wheel for focus adjustment and transverse/longitudinal moving plane table
4.electronic light source
5.high resolution color CCD video camera connected with desktop or laptop computer to provide sharp and stable image with perfect color
6.fine case made of high strength plastic material, wearable and portable
Microscope Magnification |
≥400 times |
Built-in camera pixels |
380000 pixels |
Light source |
LED |
Brightness of the light source |
≥ 600cd/m2 |
Stage |
X-Y double layer compound mechanical stage |
nailfold microcirculation microscope monitor |
color LCD monitor 8inch(4:3) |
Input&Output |
AC input 100~240V 50/60Hz DC output DC12V,2A |
Microscope Package |
Aluminum box( Size 34*29*20cm) |
Testing conditions:
1) Check the room temperature and humidity. Room temperature and humidity
should be kept relatively constant. room temperature should be maintained in the 22-24 degree , relative humidity about 70%
2) The patient generally take seats, keep the height of the hand the same with heart
3) Preparation of paraffin oil or cedar oil.Drop 2 drops in the nailfold skin. (Purpose prove light
transmission, and reduce skin scattering)
4)Testing generally be in the morning or afternoon, and review should at the same time every day .
5) The patient should
a. Avoiding intense activity or manual labor within one hour before testing
b. Take a rest about 15-30 minutes before testing
c. Can not take any drug which will affect the cardiovascular vessels before testing
d. Does not smoke , wash hands or eat within an hour before testing
e. Pay attention to the influence of the Female menstrual
Inside and outside packaging
component of the color microcirculation detector
spare parts |
Quantity |
GY880 host |
one |
LCD monitor |
one |
power adapter |
one |
cedar oil |
one |
cotton swab |
one |
chart |
one |
Our company